D-3-Clamping Unit

Generally clamping unit could be divided into:

  • Three plate: Clamping unit consisted of three major plates
  • Two plate: Clamping unit consisted of two major plates

Three plate clamping unit is consisted of 3 major plates which are machine plate for mold fixed side, plate for mold moving side, Plate for providing Movement to drive plate for mold moving side. See illustration of Three plate clamping unit in Pic.-1.

Pic.-1 Illustration of three plate clamping unit
  • Note
    White: mold
    Blue: Plat for Fixed Side(FIXED)
    Green: Plat for Moving Side(MOVABLE)
    Pink: Movement Transmission(MOVABLE)
    Purple: Platen for provide Movement(FIXED)

A later three plate clamping unit design with “Tai-bar less”, this design allows same size IMM to load bigger mold and increase productivity. See illustration in Pic.-2.

Pic.-2 Illustration of machine with/without Tai-bar (sectionA-A view in Pic.-1)
  • Note
    White: mold
    Blue: Platen for Load Mold
    Yellow: Tie-bar

Two plate clamping unit is consisted of 2 major plates which are machine plate for mold fixed side, plate for mold moving side. IMM with two plate clamping unit could provide the capacity compatible with same size IMM but less space consumption. See illustration of two plate clamping unit in Pic.-3

Pic.-3 Illustration of two plate clamping unit
  • Note
    White: Mold
    Blue: Platen for Fixed Side(FIXED)
    Green: Platen for Moving Side(MOVABLE)
    Yellow: Tie Bar (Movement Transmission)(MOVABLE)
    Red: Pump for Clamping Force

Leave a Reply